Danfoss NTZ271A4LR1B Low-Temperature Compressor Guide

Danfoss NTZ271A4LR1B Low-Temperature Compressor Guide

NTZ271A4LR1B — NTZ271A4LR1B belongs to the Danfoss Maneurop NTZ low-temperature reciprocating compressor range. Motor voltage code 4 is documented for 400 V three-phase 50 Hz and 460 V three-phase 60 Hz.

Danfoss NTZ271A4LR1B Low-Temperature Compressor Guide
NTZ271A4LR1B compressor; confirm the full nameplate before ordering.

NTZ271A4LR1B quick technical profile

Model NTZ271A4LR1B
Family Danfoss Maneurop NTZ
Application Low-temperature refrigeration
Motor code 4
Supply reference 400 V/3/50 Hz or 460 V/3/60 Hz
Packaged weight Approx. 73 kg
Commercial mode B2B quotation; no public price

Figures in this table are identification and selection references. Cooling capacity, input power and current change with refrigerant, evaporating temperature, condensing temperature, superheat, subcooling and frequency. Use the applicable manufacturer performance data for final design.

Where this compressor fits

NTZ compressors are designed for low-temperature refrigeration applications. Final capacity depends on refrigerant and operating conditions, so the exact code and Danfoss performance tables should be used for system design.

For a like-for-like service replacement, compare the full original code rather than the base model alone. Suffixes can identify electrical, oil, connection or production variations that are not interchangeable.

Critical checks before ordering

Confirm the complete suffix LR1B, refrigerant approval, start and protection components, oil return and the required evaporating range. The model code must match the electrical network and application envelope.

  • Identity: provide a readable compressor nameplate and the complete equipment model.
  • Refrigerant: confirm the existing circuit refrigerant and approved oil.
  • Electrical: verify voltage, phase, frequency, control method and protection.
  • Performance: compare capacity at the real design conditions, not only HP, TR or BTU labels.
  • Mechanical fit: check mounting centres, shell height, pipe sizes, orientation and terminals.

Replacement workflow for contractors

Diagnose the original failure before removing the compressor. Check condenser and evaporator airflow, refrigerant charge, oil return, controls, contactors or inverter output, and signs of liquid floodback or overheating. A new compressor will not survive an unresolved system fault.

Recover refrigerant correctly, keep the circuit clean and dry, replace the filter-drier where required, and flow dry nitrogen while brazing. Pressure-test with the approved gas and pressure, evacuate with a calibrated micron gauge, then charge according to the equipment documentation. Commissioning records should include voltage, current, pressures, superheat, subcooling and discharge temperature.

What to send with a quotation request

  • compressor and equipment nameplate photographs;
  • refrigerant, voltage, phase and frequency;
  • required quantity and destination country;
  • photos of terminals, pipe connections and mounting feet;
  • whether the order is an urgent replacement, project requirement or distributor stock.

This information allows RT Compressor to confirm the product before shipment and reduces wrong-part risk. View the NTZ271A4LR1B product page or use the B2B enquiry form.

Frequently asked questions

Is NTZ271A4LR1B a universal replacement?

No. Match the full code, refrigerant, electrical design, performance envelope and mechanical connections.

Why is there no public price?

RT Compressor uses B2B quotations because quantity, destination, packaging and technical confirmation affect the offer.

Can I select it by horsepower or tonnage alone?

No. Those labels do not describe capacity across the full operating envelope.

What is the fastest way to confirm availability?

Send the original nameplate, equipment model, quantity and delivery country with the enquiry.