AAD201A027G R22 380–415 V Three-Phase Compressor Guide

AAD201A027G R22 380–415 V Three-Phase Compressor Guide

AAD201A027G — AAD201A027G is listed for R22 air-conditioning duty with a 380–415 V, 50 Hz, three-phase supply. It is primarily relevant to maintenance of existing R22 equipment.

AAD201A027G R22 380–415 V Three-Phase Compressor Guide
AAD201A027G compressor; confirm the full nameplate before ordering.

AAD201A027G quick technical profile

Model AAD201A027G
Refrigerant R22
Supply 380–415 V, 3 phase, 50 Hz
Application Legacy air-conditioning service
Commercial mode B2B quotation; no public price

Figures in this table are identification and selection references. Cooling capacity, input power and current change with refrigerant, evaporating temperature, condensing temperature, superheat, subcooling and frequency. Use the applicable manufacturer performance data for final design.

Where this compressor fits

This model is intended for existing R22 systems where repair remains permitted and technically justified. Refrigerant rules differ by country, so contractors must confirm local requirements and the availability of recovered or permitted service refrigerant.

For a like-for-like service replacement, compare the full original code rather than the base model alone. Suffixes can identify electrical, oil, connection or production variations that are not interchangeable.

Critical checks before ordering

Check phase balance, contactor condition, compressor current and the original failure cause. Do not use this model in R410A, R32 or another refrigerant circuit, and do not describe it as a retrofit solution without engineering approval.

  • Identity: provide a readable compressor nameplate and the complete equipment model.
  • Refrigerant: confirm the existing circuit refrigerant and approved oil.
  • Electrical: verify voltage, phase, frequency, control method and protection.
  • Performance: compare capacity at the real design conditions, not only HP, TR or BTU labels.
  • Mechanical fit: check mounting centres, shell height, pipe sizes, orientation and terminals.

Replacement workflow for contractors

Diagnose the original failure before removing the compressor. Check condenser and evaporator airflow, refrigerant charge, oil return, controls, contactors or inverter output, and signs of liquid floodback or overheating. A new compressor will not survive an unresolved system fault.

Recover refrigerant correctly, keep the circuit clean and dry, replace the filter-drier where required, and flow dry nitrogen while brazing. Pressure-test with the approved gas and pressure, evacuate with a calibrated micron gauge, then charge according to the equipment documentation. Commissioning records should include voltage, current, pressures, superheat, subcooling and discharge temperature.

What to send with a quotation request

  • compressor and equipment nameplate photographs;
  • refrigerant, voltage, phase and frequency;
  • required quantity and destination country;
  • photos of terminals, pipe connections and mounting feet;
  • whether the order is an urgent replacement, project requirement or distributor stock.

This information allows RT Compressor to confirm the product before shipment and reduces wrong-part risk. View the AAD201A027G product page or use the B2B enquiry form.

Frequently asked questions

Is AAD201A027G a universal replacement?

No. Match the full code, refrigerant, electrical design, performance envelope and mechanical connections.

Why is there no public price?

RT Compressor uses B2B quotations because quantity, destination, packaging and technical confirmation affect the offer.

Can I select it by horsepower or tonnage alone?

No. Those labels do not describe capacity across the full operating envelope.

What is the fastest way to confirm availability?

Send the original nameplate, equipment model, quantity and delivery country with the enquiry.